Mechanical Air Filter - mestar

As one of the few devices on the market, the mestar air filter can control its exhaust volume freely. Thus, the suction power can be kept constantly at the set value for as long as possible. With the operating point setting, the filter is the ideal companion for all kinds of machine tools.

The mechanical air filter is used for the deposition of oil mist, emulsion mist, oil fumes, haze, suspended particles, oxide-containing smoke, aerosols, etc. - which makes it suitable for almost every application in industry.

Depending on the application area, the devices can be equipped with various filter stages. An extension or optimization can also be carried out later

Mechanical Air Filter - mestar

Vertical Air Filters

ML 800 to ML 1500

up to 1.700 m³/h

designation
description
usage
suction perfomance
power rating
ec-ventilation
suction collector
pre separator integrated
filter area
accessories
data sheet
ML 800 N ECDirect mount onto the mashine roofOil mist / smoke / fumes / suspended1.000 m³/h500 W X - - 4,6 m²Link
ML 1000 N ECDirect mount onto the mashine roofOil mist / smoke / fumes / suspended1.200 m³/h760 W X - - 4,6 m²Link
ML 1300 N ECDirect mount onto the mashine roofOil mist / smoke / fumes / suspended1.500 m³/h500 W X - - 7,5 m²Link
ML 1500 N ECDirect mount onto the mashine roofOil mist / smoke / fumes / suspended1.700 m³/h760 W X - - 7,5 m²Link

Horizontal Air Filters

ML 802 to ML 1502

uo to 1.700 m³/h

designation
description
usage
suction perfomance
power rating
ec-ventilation
suction collector
pre separator integrated
filter area
accessories
data sheet
ML 802 NAS ECIndirectly mount by pipe- or tube-connectionOil mist / smoke / fumes / suspended1.000 m³/h500 W X X - 4,6 m²Link
ML 1002 NAS ECIndirectly mount by pipe- or tube-connectionOil mist / smoke / fumes / suspended1.200 m³/h760 W X X - 4,6 m²Link
ML 1302 NAS ECIndirectly mount by pipe- or tube-connectionOil mist / smoke / fumes / suspended1.500 m³/h500 W X X - 6,8 m²Link
ML 1502 NAS ECIndirectly mount by pipe- or tube-connectionOil mist / smoke / fumes / suspended1.700 m³/h760 W X X - 6,8 m²Link

Consumeable Supplies

  • Pre / after filter G2
  • Prefilter complete G4
  • Prefilter exchange-fleece G4
  • Filter panels F9
  • Afterfilter HEPA H13
  • Afterfilter active-carbon

System Control

The indusa control system allows a matching of filtration, heat recovery and air-conditioning.

• Airflow control adapted to the demand, e.g. Via flap control or vacuum control
• Heat recovery and filtration via joint fans
• Control and visualization via panel, web and mobile devices
• Temperature monitoring of the pipeline, for fire detection
• Machine interfaces for signal exchange and safety shutdown
• Energy measurement of all relevant parameters
• Complete connection to the building control system, incl. Data exchange (OPC, BACnet)
• Filter monitoring: suction power, maintenance, error message, temperature and other relevant variables
• Modular design for later extensions
• Steel construction including assembly and statics
• Installation of the machine- and hall-exhaust ducts as well as the fresh-air piping (air conditioning)
• Customized measuring and control technology

Let us know your requirements, we will be pleased to advise you.

Equipment Options

  • External fault detection relay
    For the transmission of all error messages collected or individually via potential-free contacts.
  • switch-on- relay
    For remote switching of the air filter, e.g. Via the machine control, in all voltages.
  • Air flow monitor
    For the safety-relevant query of the air flow, e.g. In case of explosion hazard.
  • Flow monitoring
    For monitoring the minimum required volume flow for machine suction.
  • Flow control
    For automatic control of the volume flow with variable resistance in the air system, two operating points (switchable via external signal).
  • Operating point switching
    For switching between different machine states to drive different suction capacities.
  • Connection for IT or TT systems
    Integration of various transformers for networks without neutral conductors. Available in different voltages, standard 400V.
  • Connector
    Directly at the filter system, for the connection of power and signal exchange directly via the desired plug-in connection.
  • Power switch
    Integrated in control cabinet, for manual shutdown of the system directly on the device.
  • External speed controller
    Accessible from the outside via the control cabinet or via cable-wired remote control.
  • Time regulation
    After withdrawing the switch-on signal, the filter continues to run for a certain time in order to completely absorb all the emissions in the work area.
  • Safety circuit
    Various security devices e.g. In the case of fire-endangering materials.
  • Reinforced fans
    Reinforced fans are available for all our filter systems and can thus be optimally adapted to the exact application. Of course always in EC technology.
  • RAL special colors
    All our devices can be produced in any RAL color. The standard color is RAL 7035.
  • Extended Warranty
    The warranty extension will give you additional predictable security and is available as an extension by 1 year or by 2 years.
  • PLC control
    Control and visualization via a separate touchpanel, via the web or mobile devices. Integration into the building control system is also possible

Accessories

For our elstar products, we offer a wide range of accessories.

Amongst other things:
• Drip frame
• Wheel stand incl. collecting container
• drip tray
• wall mount
• 4-foot stand
• single-foot stand

Spezial Equipment

We are developing custimized spezial equipment as:

  • Cyclone seperator
  • Collectors and outlet collectors
  • Prefilter
  • Eletrostatic filter
  • Van
  • Silencer
Top